Product Center

IM-100.jpg
+
  • IM-100.jpg

IM-100 Precision Engineering Surveying Instrument


A professional, high-precision, high-quality, and high-stability precision engineering total station. It adopts advanced technologies such as RED-tech EX new distance measurement technology, high-end EDM, and IACS autonomous angle calibration system, with an IP66 high protection level; It has a machine-mounted SDR Basic software with rich functions, meeting the measurement needs of different users.

Keywords:

Measurement Digitalization

Category:

Product Overview


Features
1. 32-hour ultra-long battery life for a single battery
2. Professional SDR Basic measurement program
3. Customizable operation interface menu
4. Built-in angle self-calibration system
5. IP66 ultra-high industrial-grade dust and water resistance
6. Faster trigger key for greater convenience and efficiency
7. Liquid dual-axis compensator, ±6′ ultra-large compensation range
Technical Specifications
Model iM-101 iM-102
Telescope
Magnification/Resolution 30x/2.5"
Other Barrel length: 171mm, objective lens diameter: 45mm (EDM: 48mm)
Imaging: Erect image, Field of view: 1°30′ (26m, 1,000m)
Minimum focusing distance: 1.3m, Reticle illumination: 5-level brightness
Theodolite
Minimum reading 0.1″/1″ 0.5″/1″
Angular accuracy (JJG414-94) 1″ 2″
Dual-axis compensator Liquid dual-axis tilt sensor, compensation range ±6′
Collimation error correction Provided
EDM
Laser output *1 Prism-less mode: Class 3R, Prism/Reflector mode: Class 1
Measuring range
(Under normal weather conditions
*2 )
Prism-less *3 0.3~1,000m *4
Reflector *5/*6 RS90N-K: 1.3~500m
Mini prism CP01: 1.3~2,500m
OR1PA: 1.3~500m
Single prism 1.3~6,000m *4
Minimum reading Precision/Rapid measurement: 0.0001m/0.001m (optional)
Tracking/Road surface: 0.001m/0.01m (optional)
Accuracy *2 (JJG703-90)
D=distance measurement value, unit mm)
Prism-less *3 (2+2ppm x D) mm *8
Reflector *5/*6 (2+2ppm x D) mm
Prism *7 (1.5+2ppm x D) mm
Measurement time *4/*9 Precision measurement: 0.9s (1.5s initial), Rapid measurement: 0.6s (1.3s initial),
Tracking measurement: 0.4s (1.3s initial)
Operating System, Interfaces and Data Management
Operating system Linux
Display/Keyboard Backlit, adjustable contrast, 192 x 80 dot matrix graphic LCD, backlit 28-key alphanumeric keyboard
Operation Panel Double-sided
Data storage Memory Approximately 50,000 points
External storage USB flash drive (maximum 32GB)
Interface RS-232C serial port, USB2.0 (Type A for USB flash drive)
Bluetooth (optional) *14 Bluetooth Class 1.5, Ver.4.1+EDR, operating range 10m *10
Other
Targeting light *11 Coaxial red laser EDM beam
Guiding light *11 LED (red light 626nm/green light 524nm)
Operating range: 1.3~150m
Level Circular level 6′ (inner circle)
Circular Level 10′/2 mm
Centering Device Optical Centering Device (Optional) Magnification: 3x, Shortest Focal Length: 0.5m from the base bottom
Laser Centering Device (Standard) Red Laser Diode (635nm±10nm), Spot Accuracy: ≤1.0
mm@1.3m, Class 2 Laser Product
Dust and Water Resistance Grade / Operating Temperature IP66 (IEC 60529: 2001) / -20~+60℃
Dimensions (including handle) / Instrument Height 183x181x348mm/192.5mm from base surface
Weight (including handle and battery) Approximately 5.3kg
Power System
Battery / Operating Time (20℃) *12/*15 BDC72 Rechargeable Lithium Battery / BDC72 Battery: Approximately 32 hours *13
*1 IEC60825-1:Ed3:0:2014/FDA CDRH 21 CFR Part 1040.10 and 11.
*2 General weather conditions: light fog, visibility approximately 20km, sunny, slight atmospheric heat shimmer.
*3 Test results using a Kodak gray card with 90% reflectance white surface, when the measured object surface brightness is less than or equal to 30000lx; The prism-free measurement range and accuracy will vary depending on the reflectivity of the measurement target, weather conditions, and the environment.
*4 Good weather conditions: no fog, visibility approximately 40km, cloudy, no atmospheric heat shimmer.
*5 Test results when the angle of incidence of the ranging beam and the reflector is within 30°.
*6 When the temperature range is 50~60℃: RS90N-K: 1.3~300m, RS50N-K: 1.3~180m, RS10N-K: 1.3~60m.
*7 The orientation of the prism deviates from the instrument within 10m during measurement.
*8 The measured distance is within the range of 0.3~200m.
*9 The fastest measurement speed for good weather conditions, compensation off, correct receiving adjustment, and inclined distance measurement.
*10 No obstacles near the instrument, few passing vehicles, no radio transmission or interference sources, and no rain.
*11 Pointing light and guiding light cannot work simultaneously.
*12 Values may vary due to environmental factors such as temperature and observation conditions.
*13 Using ECO mode.
*14 Bluetooth wireless technology usage licenses may vary depending on the country or region; please consult your local dealer or office in advance.